NM4-I Installation


Roles: Plumbers, Certified Installers
Last updated: June 2025

NextMeter 4-Indoor Hello (Lidless).svg

Installation


1. Attach meter couplings

Secure couplings set to the water line and place new gaskets in each end.

Secure couplings set to water line.svg

2. Ensure correct spacing

The water line should be parallel and should have a spacing of 7.5"or 190.5 mm.

Ensure that the water line is parallel.svg

Caution

Spacing should allow for meter without pushing, pulling, or kinking the line.

3. Secure the NextMeter

Place the NextMeter and tighten both ends to a max torque of 11 ft-lb using a flat jaw or monkey-style wrench.

Place meter and tighten both ends.svg

Caution

Do NOT overtighten meter couplings as this may result in the gaskets not forming a proper seal


Pressurize the water line and check for any leaks at both connection points

Pressurize line and check for leaks.svg

4. Verify NextMeter communication

Open the NextMeter register lid. The Meters’s RF LED will blink green when it is able to communicate with its Gateway.

Communication Between NextMeter and Gateway.svg


Note

The NextMeter must be programmed in the NextCentury Cloud and its Gateway must be online, in order for it to begin communicating with its Gateway.