NM4-I Installation
Roles: Plumbers, Certified Installers
Last updated: September 2023
Installation
1. Attach meter couplings
Secure couplings set to the water line and place new gaskets in each end.
2. Ensure correct spacing
The water line should be parallel and should have a spacing of 7.5"or 177.8 mm.
Caution
Spacing should allow for meter without pushing, pulling, or kinking the line.
3. Secure the NextMeter
Place the NextMeter and tighten both ends to a max torque of 11 ft-lb using a flat jaw or monkey-style wrench.
Caution
Do NOT overtighten meter couplings as this may result in the gaskets not forming a proper seal
Pressurize the water line and check for any leaks at both connection points
4. Verify NextMeter communication