The Equipment page is where you program a property's devices one at a time: the Gateway, Repeaters, and each unit's Transceivers, Remote Readers and Leak Sensors. For programming a new property or making large changes, we recommend the Program page.
Before you start
The property needs a listing with its buildings and units. See Create a property listing, then add the buildings and units: see Add buildings and units below, or Program a new property on the Program page.
- Upgrading a property with 3rd Party equipment? See 3rd Party Equipment Upgrade.
- Have the programming in a spreadsheet already? See Program a property with the CSV Uploader, or Import an Inovonics property for .SDF and .BAK files.
Scan serial numbers, don't type them
Serial numbers are easy to misread or mistype. Use a barcode scanner, or the Cloud Scanner in the NCSS mobile app, whenever you enter one.
Add buildings and units
On the property's Equipment page, select + Add:
- Add a Unit: one unit. Choose its building, name it, and pick a utility type to start programming it.
- Add Multiple Units: several units in a building that already exists.
- Add a Building: a new building and its units.
Add a building
Select + Add, then Add a Building.
In Name, type the building's name and select it with (Create New). Add a Description if you like.
Under # of Units, enter how many units the building has. With Auto Increment on, name the first unit and the others are numbered after it (Unit 1, Unit 2 and so on). You can change any name. Then select Save.
Add Multiple Units opens the same window, but with an existing building already in Name (Add a Building leaves it empty). Keep it to add units to that building, or type a new name to create a building.
Program the Gateway and Repeaters
Open the property, select Equipment, then the Network tab.
Select the Gateway's Serial Number field and scan the barcode. It's on the back of the Gateway and on its box.
Under Repeaters, select the Serial Number field and scan each Repeater's barcode. It's on the back of the Repeater and on its box.
Add a location, description and comments
Select a Gateway or Repeater to open its details.
- Location: drag the device icon on the map to where the device is, or will be, installed.
- Description: notes about where the device is.
- Comments: anything else worth knowing.
Program a device on a unit
This covers Transceivers, Remote Readers and Leak Sensors. To see a unit's reads and details afterwards, or add notes, see The Unit Details page.
Open the property and select Equipment. On the Units tab, find the unit and select Program a Device.
Select a utility type, or Leak Sensor.
If the unit already has a utility type but no device, you go straight to the Program a Device field instead. You can change the utility type there if you need to.
Scan the device's barcode into the serial number field.
The barcode is on the side of the Transceiver.
The barcode is on the face of the device below the display.
The barcode is on the side of the LS4. Enter its location and a short description, then skip to step 6.
3rd party devices can only be programmed through a file upload, when a 3rd party system is first upgraded. If a 3rd party device stops working, replace it with a NextCentury device.
For more about upgrading a 3rd party property, see 3rd Party Equipment Upgrade.
Choose the meter type. The Meter Type menu lists meters you've already used for this utility; for a new one, use the Meter Builder. The meter type fills in the multiplier and unit of measure, which are required and stay highlighted in red until they're filled in.
If the device is connected to a pulse output meter, also enter an IMR (Initial Meter Read). For RR4-TRs, select the meter signal type. To set up a second meter, select + Add Meter on Port 2.
Recommended: enter the meter serial number. Optional: add a custom ID.
Select Save Unit to save your changes, or Cancel to discard them.
Add another utility to a unit
A unit can have a device for each utility, for example cold and hot water.
Select the unit, then Edit.
Select + Add a New Meter, then choose the utility type to add.
Program the new utility's device the same way, from step 3 above, and select Save Unit.
What happens next
Once you save, the programming syncs to the Gateway automatically.