View and resolve alerts

When something needs attention at a property, an alert appears on the property's Alerts page. This article shows how to find your active alerts and what to do about each type. For what each alert means, see Health and security alerts.

View active alerts

In the Web Portal, open the property, then select Alerts in the property menu. The page lists every active alert at the property.

Web portal with a property open. In the left menu, under the property name, a red arrow points to Alerts, between Reports and Live Feed. The Alerts page lists the property's active alerts, here several Battery alerts reading Battery level is getting low, each with its unit, utility type (Hot Water or Cold Water) and date. The Alerts, Settings, and Notifications tabs are in the upper-right corner, with Alerts selected.

Select an alert's unit to open the Unit page.

Web portal Alerts page for a property. The first alert, a Connection alert reading Device hasn't connected since Dec 8th 21, is ticked, and Dismiss Selected shows above the list. A red arrow points to the alert's unit, a blue link in the middle of the row (1265 - Unit 2 in this example): select it to open the Unit page. Below are Consumption, Battery, and more Connection alerts.

The unit's alerts are listed under Open Alerts.

Web portal Unit page (breadcrumb: property name, then Equipment, then the unit, 1265 - Unit 2 in this example), on the Cold Water tab. At the top is the current read, 441,676 Gallons in this example. Under the Transceiver on the right, a red arrow points to 2 Open Alerts, opened to list the Battery and Connection alerts with the date each was opened.

Tamper

A Tamper alert means a device has been physically opened, even if it was opened by someone authorized, for an inspection or maintenance. A Tamper alert at the same time as unusual usage can be a sign that someone is tampering with the equipment, though it can have other causes too.

In the Alerts list, it looks like this:

A Tamper alert in the Alerts list: Tamper, Device plastics have been opened, for 1255 - Unit 1 in this example, Cold Water, dated Oct 12, 2021.

What to do: Visit the device and check that it's installed correctly. Fix anything you find, like an open cover or a device that's off its mounting plate.

Transceiver

Close the cover. It clicks shut when it's closed properly.

Side view of an open Transceiver: the cover is tilted up above the base, and the battery and inside parts show underneath. A curved red arrow at the left points down: swing the cover down onto the base to close it. Side view of the same Transceiver with its cover closed flat on the base. Small red lines at the left edge, where the cover meets the base, show it clicking shut.

Remote Reader

Put the Remote Reader display back on its mounting plate, then lock the security tab.

A Remote Reader display (Model: RR4-TR) being put back on its mounting plate. The plate is behind, with the wired terminal block showing, and the display is tilted over it at the upper right. A curved red arrow points down and left: lower the display onto the plate. A straight red arrow points down at the security tab at the bottom edge of the plate, which is outlined in red. The Remote Reader display seated on its mounting plate. A red arrow points up at the security tab at the bottom edge, which is outlined in red: push the tab up to lock the display in place.

Connection

A Connection alert means a device has gone offline. Usually there's a reason somewhere else on the property, and the pattern of alerts helps you find it.

In the Alerts list, it looks like this:

A Connection alert in the Alerts list: Connection, Device hasn't connected since Dec 8th 21, for 1265 - Unit 2 in this example, Cold Water, dated Dec 12, 2021.

What to do: Work out where in the connection chain the problem is (the Gateway, a Repeater, or a single device), then check that part. See Troubleshoot a Connection alert for the checks for each device.

Power Loss

A Power Loss alert means a wall-powered device, like a Gateway or Repeater, has been unplugged or lost power. Often it was unplugged by accident and just needs plugging back in.

In the Alerts list, it looks like this:

A Power Loss alert in the Alerts list: Power Loss, with a plug icon, for a Repeater location, dated Sep 08, 2021.

What to do: Make sure the power cord is plugged in firmly at the device and at the outlet. If it is and the alert hasn't cleared, check that the outlet has power: a power outage or a tripped breaker can cut it. The alert clears once the power is back.

Repeaters need to be at least three feet from GFCI outlets, to avoid interference (see the RE4 Quick Start Guide).

Left: a GFCI outlet (with RESET and TEST buttons) inside a faint circle, with faint arrows marked 3 feet from the outlet to the circle. Its power supply's cord runs to the side of a Repeater (the NEXT logo on its front, the word Repeater in the lower-left corner), which sits outside that circle. Right: a GFCI outlet inside a solid pink circle, with arrows marked 3 feet pointing up, down, left, and right from the outlet to the circle: keep the Repeater at least three feet from a GFCI outlet.

Battery

A Battery alert means a battery is getting close to the end of its life. It applies to battery-powered equipment: Transceivers, Remote Readers, NextMeter Indoors, NextLinks, NextRegisters, and Leak Sensors.

In the Alerts list, it looks like this:

A Battery alert in the Alerts list: Battery, Battery level is getting low, for 1265 - Unit 2 in this example, Cold Water, dated Dec 03, 2021.

What to do: Replace the battery. Our battery replacement kits make it quick and easy. If you have concerns about battery life, contact our support team.

Temperature

A Temperature alert warns you when a water meter is close to freezing, so you can act before it's damaged. You also get one when the temperature at a device is outside the safe operating range for NextCentury equipment.

In the Alerts list, it looks like this:

A Temperature alert in the Alerts list, with a thermometer icon: Device reached freezing temperature, for 3000 - Unit 3031 in this example, Cold Water, dated Nov 25, 2019.

What to do: Bring the space back to a normal temperature: for example, close an open window or door, adjust the thermostat, or move the device away from whatever is making it too hot or cold.

Don't heat equipment directly

Don't apply heat directly to electronic devices, meters, or pipes.

Consumption

A Consumption alert means usage has changed suddenly. NextCentury equipment and cloud analytics work together to catch even small changes, like a running toilet.

In the Alerts list, it looks like this:

A Consumption alert in the Alerts list, with a rising-line icon: Meter leak alert detected, for 1265 - Unit 502 in this example, Hot Water, dated Dec 10, 2021.

What to do: Check every faucet and fixture for open valves and leaks, and close or fix any you find.

Check toilets too: their leaks can be hard to see, and they're usually caused by a worn or faulty flapper. To test a toilet, put a few drops of food coloring in the tank. If the color shows up in the bowl within 15 minutes, the toilet is leaking and the flapper should be replaced. Flush afterwards so the bowl doesn't stain.

For help monitoring leaks, see our Leak Monitoring Solution.